• product_banner_01

Iimveliso

Entsha!Ukusebenza okuphezulu kwe-Ethernet Layer3 100G Tshintshela

Ezona mpawu:

24*10GE(SFP+), 2*40/100GE(QSFP28)

Ukukwazi ukulala komgca we-Ethernet eluhlaza, ukusetyenziswa kwamandla aphantsi

IPv4/IPv6 imisebenzi yendlela engatshintshiyo

I-RIP/OSPF/RIPng/OSPFv3/PIM kunye nezinye iindlela zokuziphatha

I-VRRP/ERPS/MSTP/FlexLink/MonitorLink ikhonkco kunye neeprothokholi zokungasebenzi kwenethiwekhi

Indlela yokucoca ukhuseleko lwe-ACL kunye nokubonelela ngemisebenzi yokulawula ukhuseleko ngokusekelwe kwi-MAC, IP, i-L4 port kunye nenqanaba le-port

Umsebenzi wokuhlalutya isibuko sezibuko ezininzi, uhlalutyo lwesipili olusekwe kwinkonzo yokuhambahamba

O&M : Web/SNMP/CLI/Telnet/SSHv2


IIMPAWU ZEMVELISO

IIPARAMETER

Iithegi zeMveliso

Sinyanzelisa ukubonelela ngemveliso ekumgangatho ophezulu kunye nembono yamashishini amancinci aphezulu, iingeniso ezinyanisekileyo kunye neyona nkonzo ilungileyo nekhawulezayo.ayizukuzisela kuphela imveliso ekumgangatho ophezulu kunye nenzuzo enkulu, kodwa enye yezona zinto zibalulekileyo iya kuba kukuhlala kwimarike engapheliyo yeNew!Umgangatho oPhezulu we-Ethernet Layer3 100G Tshintsho, Wamkelekile kuhambo lwakho kunye nayo nayiphi na imibuzo yakho, sinethemba elinyanisekileyo lokuba sinokuba nethuba lokusebenzisana nawe kwaye sinokwakha ubudlelwane obubanzi beshishini elincinci kunye nawe.
Sinyanzelisa ukubonelela ngemveliso ekumgangatho ophezulu kunye nembono yamashishini amancinci aphezulu, iingeniso ezinyanisekileyo kunye neyona nkonzo ilungileyo nekhawulezayo.ayizi kukuzisela kuphela imveliso ekumgangatho ophezulu kunye nenzuzo enkulu, kodwa enye yezona zinto zibalulekileyo iya kuba kukuhlala kwimarike engapheliyo.I-China Poe kunye nexabiso le-LAN, Kwiminyaka emininzi yenkonzo elungileyo kunye nophuhliso, sineqela leentengiso zorhwebo lwamazwe ngamazwe olufanelekileyo.Iimpahla zethu zithunyelwe kuMntla Melika, eYurophu, eJapan, eKorea, eOstreliya, eNew Zealand, eRashiya nakwamanye amazwe.Sijonge phambili ukwakha intsebenziswano elungileyo kunye nexesha elide kunye nawe kwixesha elizayo!

Iimpawu eziphambili

I-S5354XC yi-Layer-3 uplink switch elungiselelwe nge-24 x 10GE + 2 x 40GE / 2 x 100GE.Isofthiwe isekela i-ACL indlela yokucoca ukhuseleko, ulawulo lokhuseleko olusekelwe kwi-MAC, IP, L4, kunye namanqanaba e-port, uhlalutyo lwe-mirroring ye-multi-port, kunye nohlalutyo lomfanekiso olusekelwe kwiinkqubo zenkonzo.Isoftware kulula ukuyilawula kwaye ibhetyebhetye ukuyifaka, kwaye inokuhlangabezana neemeko ezahlukeneyo ezinzima.

FAQ

I-Q1: Ngaba ndingabeka uphawu lwethu kunye nemodeli kwiimveliso zakho?

A: Ngokuqinisekileyo, sixhasa i-OEM kunye ne-ODM esekelwe kwi-MOQ.

I-Q2: Yintoni i-MOQ yakho ye-ONT kunye ne-OLT?

Kwi-batch order, i-ONT ngama-2000 eeyunithi, i-OLT ngama-50 eeyunithi.Amatyala akhethekileyo, sinokuxoxa.

I-Q3: Ngaba ii-ONT / OLTs zakho zinokuhambelana nemveliso yomntu wesithathu?

A: Ewe, ii-ONT/OLTs zethu ziyahambelana nemveliso yomntu wesithathu phantsi kweprotocol eqhelekileyo.

I-Q4: Lide kangakanani ixesha lakho lewaranti?

A: unyaka omnye.

Yintoni i-SWITCH?

Ukutshintsha kuthetha "ukutshintsha" sisixhobo senethiwekhi esisetyenziselwa ugqithiso lombane (lokukhanya) kombane.Inokubonelela ngendlela ekhethekileyo yomqondiso wombane kuzo naziphi na iinodi zenethiwekhi ezimbini ezifikelela kutshintsho.Olona tshintsho luxhaphakileyo lutshintsho lwe-Ethernet.Ezinye eziqhelekileyo kukutshintsha kwelizwi lomnxeba, utshintsho lwefayibha, njl.njl.Kwimeko yetekhnoloji eguquka ngokukhawuleza, amashishini kunye nemibutho iya ixhomekeke ngakumbi kwiziseko zonxibelelwano ezithembekileyo nezisebenzayo ukuxhasa imisebenzi yazo.Ngokunyuka okuthe gqolo komthamo wedatha kunye nesidingo sokuqhagamshelwa kwesantya esiphezulu, kuye kwaba yimfuneko ukuba ube nokutshintsha kwenethiwekhi olomeleleyo onokuhlangabezana nezi mfuno.Apha kulapho i-LIMEE entsha yokusebenza okuphezulu kwe-Ethernet Layer3 100G Switch iza kudlala.

Olu tshintsho olucekethekileyo lweLayer3 ludibanisa inkqubela phambili yamva nje kwitekhnoloji yenethiwekhi ukubonelela amashishini ngokusebenza okungenakuthelekiswa nanto, ukulinganisa, kunye nokuthembeka.Eyenzelwe ukujongana nokunyuka kwedatha yedatha, lo tshintsho luqhayisa i-bandwidth ye-100G, evumela uxhulumaniso olungenamthungo kunye nokudluliselwa kwedatha kwinethiwekhi.

Enye yezinto ezibalaseleyo zolu tshintsho kukukwazi kwayo Amandla phezu kwe-Ethernet (PoE).Kuthetha ukuba ayikwazi ukuhambisa idatha kuphela kodwa inika amandla kwizixhobo ezixhunyiwe ezifana neefowuni ze-IP, iindawo zokungena ezingenazintambo, kunye neekhamera zokhuseleko, ukuphelisa isidingo semithombo yamandla eyongezelelweyo.Oku akwenziwa lula kuphela inkqubo yofakelo kodwa ikwabonelela ngokuguquguquka ekubekweni kwesixhobo, kuyenza ibe sisisombululo esifanelekileyo kumashishini abo bonke ubungakanani.

Ke ngoko, unikezelo lwamandla amabini luqinisekisa ukuba uthungelwano luhlala lusebenza kwaye lusebenza nakwimeko yokusilela kombane.Oku kungasebenzi kuphelisa naliphi na ixesha lokunciphisa elinokwenzeka, ukuqinisekisa imveliso engaphazamisekiyo kunye nokunciphisa ilahleko.Ngokukwazi ukuphatha i-traffic network enzima kunye namandla ezixhobo ezininzi, olu tshintsho lubonelela ngoxolo lwengqondo kumashishini axhomekeke kwisiseko sothungelwano esithembekileyo.

Ukongeza kwiimpawu zayo eziphambili, olu tshintsho lweLayer3 lukwabonelela ngojongano lolawulo olulungele umsebenzisi, luvumela abalawuli ukuba baqwalasele ngokulula kwaye babeke iliso kwinethiwekhi.Ngeempawu ezifana nenkxaso ye-VLAN, ukubeka phambili kwe-QoS, kunye neeprothokholi zokhuseleko eziphambili, amashishini anokwandisa ukusebenza kwenethiwekhi kunye nokuqinisekisa ukuthembeka kwedatha.

Nge-LIMEE entsha yokusebenza okuphezulu kwe-Ethernet Layer3 100G Tshintshela, amashishini anobungqina bexesha elizayo kwiziseko zabo zenethiwekhi kunye nokuqinisekisa uxhulumaniso oluphezulu, ukuhanjiswa kwamandla, kunye nokulawulwa kwenethiwekhi.Nokuba lishishini elikhulu, iziko lemfundo, okanye ishishini elincinci, olu tshintsho luzisa ukusebenza okugqwesileyo kunye nokuthembeka, oko kuyenza ibe yi-asethi exabisekileyo kule mihla yedijithali.Ngoko, kutheni ulinda?Phucula kwi-Ethernet Layer3 100G entsha yokusebenza okuphezulu kwaye ufumane amandla onxibelelwano olungenamthungo kunye nokusebenza kwenethiwekhi okuphuculweyo namhlanje!


  • Ngaphambili:
  • Okulandelayo:

  • IiNkcazo zeMveliso

    Ukonga amandla

    Ukukwazi ukulala komgca we-Ethernet eluhlaza

    Ukutshintsha kweMAC

    Lungiselela ngokuzinzileyo idilesi ye-MAC

    Ukufunda idilesi ye-MAC ngokukhawuleza

    Qwalasela ixesha lokuguga ledilesi ye-MAC

    Nciphisa inani ledilesi ye-MAC efundiweyo

    Uhluzo lwedilesi ye-MAC

    IEEE 802.1AE Ulawulo loKhuseleko lweMacSec

    I-Multicast

    IGMP v1/v2/v3

    IGMP Snooping

    IGMP ikhefu ngokukhawuleza

    I-MVR, i-Multicast filter

    Iipolisi ezininzi kunye nemida yeenombolo ezininzi

    Ukusasazwa kwetrafikhi okuninzi kuzo zonke iiVLAN

    VLAN

    4K VLAN

    GVRP

    QinQ, QinQ ekhethiweyo

    I-VLAN yabucala

    Ukungafuneki kweNethiwekhi

    VRRP

    Ukhuseleko lwekhonkco lwe-ethernet oluzenzekelayo lwe-ERPS

    MSTP

    I-FlexLink

    MonitorLink

    802.1D(STP),802.1W(RSTP),802.1S(MSTP)

    Ukukhuselwa kwe-BPDU, ukukhuselwa kweengcambu, ukukhuselwa kwe-loop

    I-DHCP

    Iseva ye-DHCP

    I-DHCP Relay

    DHCP Client

    I-DHCP Snooping

    ACL

    Umaleko 2, uLeya 3, kunye noMaleko 4 ACLs

    IPv4, IPv6 ACL

    VLAN ACL

    Umzila

    IPV4/IPV6 iprothokholi yemfumba emibini

    IPv6 ummelwane ukufunyanwa, Indlela MTU ukufunyanwa

    Indlela engatshintshiyo, RIP/RIPng

    OSFPv2/v3,PIM indlela eguquguqukayo

    BGP, BFD for OSPF

    MLD V1/V2, MLD snooping

    QoS

    Ukuhlelwa kwetrafikhi okusekwe kwimihlaba ekwisihloko seprotocol ye-L2/L3/L4

    Umlinganiselo wezithuthi zemoto

    Phawula i-802.1P/DSCP ephambili

    SP/WRR/SP+WRR ukucwangcisa umgca

    Iindlela zokuthintela ukuxinana komsila kunye ne-WRED

    Ukujongwa kwetrafikhi kunye nokubunjwa kwetrafikhi

    Uphawu loKhuseleko

    Ukuqatshelwa kwe-ACL kunye nokucoca indlela yokukhusela esekelwe kwi-L2 / L3 / L4

    Ikhusela ekuhlaselweni kwe-DDoS, ukuhlaselwa kwe-TCP SYN yeSikhukula, kunye nokuhlaselwa kwe-UDP yeSikhukula

    Cindezela usasazo oluninzi, usasazo, kunye neepakethi ezingaziwayo zeunicast

    Ukwahlulwa kwezibuko

    Ukhuseleko lwezibuko, IP+MAC+isibophelelo sezibuko

    I-DHCP sooping, iDHCP inketho82

    IEEE 802.1x isatifikethi

    Tacacs +/Radius ungqinisiso olukude lomsebenzisi, ukuqinisekiswa komsebenzisi wasekhaya

    I-Ethernet OAM 802.3AG (CFM), 802.3AH (EFM) ubhaqo lwekhonkco elihlukeneyo le-Ethernet

    Ukuthembeka

    Ikhonkco lokudibanisa kwimo ye-static / LACP

    Ubhaqo lwekhonkco lwendlela enye ye-UDLD

    I-ERPS

    I-LLDP

    Ethernet OAM

    1+1 ugcino lwamandla

    OAM

    Console, Telnet, SSH2.0

    ULawulo lweWEBHU

    I-SNMP v1/v2/v3

    Ujongano Lwenyama

    Izibuko le-UNI

    24*10GE, SFP +

    NNI Port

    2 * 40/100GE, QSFP28

    Izibuko loLawulo lwe-CLI

    RS232, RJ45

    Indawo yokusebenza

    sebenzisa i-temp

    -15℃55℃

    Ubushushu bokugcina

    -40℃70℃

    Ubuntu bezizalwane

    10%~90%(Akukho ukuxinana)

    Ukutya umbane

    Ukunikezwa Amandla

    1+1 unikezelo lwamandla amabini, AC/DC amandla okuzikhethela

    Ubonelelo lwaMandla oNgeniso

    AC: 90~264V, 47~67Hz;DC: -36V~-72V

    Ukutya umbane

    Umthwalo opheleleyo ≤ 125W, ungasebenzi ≤ 25W

    Ubungakanani besakhiwo

    Iqokobhe letyala

    Igobolondo lesinyithi, ukupholisa umoya kunye nokutshatyalaliswa kobushushu

    Case dimension

    19 intshi 1U, 440*320*44 (mm)

     