Sinyanzelisa ukubonelela ngemveliso ekumgangatho ophezulu kunye nembono yamashishini amancinci aphezulu, iingeniso ezinyanisekileyo kunye neyona nkonzo ilungileyo nekhawulezayo.ayizukuzisela kuphela imveliso ekumgangatho ophezulu kunye nenzuzo enkulu, kodwa enye yezona zinto zibalulekileyo iya kuba kukuhlala kwimarike engapheliyo yeNew!Umgangatho oPhezulu we-Ethernet Layer3 100G Tshintsho, Wamkelekile kuhambo lwakho kunye nayo nayiphi na imibuzo yakho, sinethemba elinyanisekileyo lokuba sinokuba nethuba lokusebenzisana nawe kwaye sinokwakha ubudlelwane obubanzi beshishini elincinci kunye nawe.
Sinyanzelisa ukubonelela ngemveliso ekumgangatho ophezulu kunye nembono yamashishini amancinci aphezulu, iingeniso ezinyanisekileyo kunye neyona nkonzo ilungileyo nekhawulezayo.ayizi kukuzisela kuphela imveliso ekumgangatho ophezulu kunye nenzuzo enkulu, kodwa enye yezona zinto zibalulekileyo iya kuba kukuhlala kwimarike engapheliyo.I-China Poe kunye nexabiso le-LAN, Kwiminyaka emininzi yenkonzo elungileyo kunye nophuhliso, sineqela leentengiso zorhwebo lwamazwe ngamazwe olufanelekileyo.Iimpahla zethu zithunyelwe kuMntla Melika, eYurophu, eJapan, eKorea, eOstreliya, eNew Zealand, eRashiya nakwamanye amazwe.Sijonge phambili ukwakha intsebenziswano elungileyo kunye nexesha elide kunye nawe kwixesha elizayo!
I-S5354XC yi-Layer-3 uplink switch elungiselelwe nge-24 x 10GE + 2 x 40GE / 2 x 100GE.Isofthiwe isekela i-ACL indlela yokucoca ukhuseleko, ulawulo lokhuseleko olusekelwe kwi-MAC, IP, L4, kunye namanqanaba e-port, uhlalutyo lwe-mirroring ye-multi-port, kunye nohlalutyo lomfanekiso olusekelwe kwiinkqubo zenkonzo.Isoftware kulula ukuyilawula kwaye ibhetyebhetye ukuyifaka, kwaye inokuhlangabezana neemeko ezahlukeneyo ezinzima.
I-Q1: Ngaba ndingabeka uphawu lwethu kunye nemodeli kwiimveliso zakho?
A: Ngokuqinisekileyo, sixhasa i-OEM kunye ne-ODM esekelwe kwi-MOQ.
I-Q2: Yintoni i-MOQ yakho ye-ONT kunye ne-OLT?
Kwi-batch order, i-ONT ngama-2000 eeyunithi, i-OLT ngama-50 eeyunithi.Amatyala akhethekileyo, sinokuxoxa.
I-Q3: Ngaba ii-ONT / OLTs zakho zinokuhambelana nemveliso yomntu wesithathu?
A: Ewe, ii-ONT/OLTs zethu ziyahambelana nemveliso yomntu wesithathu phantsi kweprotocol eqhelekileyo.
I-Q4: Lide kangakanani ixesha lakho lewaranti?
A: unyaka omnye.
Yintoni i-SWITCH?
Ukutshintsha kuthetha "ukutshintsha" sisixhobo senethiwekhi esisetyenziselwa ugqithiso lombane (lokukhanya) kombane.Inokubonelela ngendlela ekhethekileyo yomqondiso wombane kuzo naziphi na iinodi zenethiwekhi ezimbini ezifikelela kutshintsho.Olona tshintsho luxhaphakileyo lutshintsho lwe-Ethernet.Ezinye eziqhelekileyo kukutshintsha kwelizwi lomnxeba, utshintsho lwefayibha, njl.njl.Kwimeko yetekhnoloji eguquka ngokukhawuleza, amashishini kunye nemibutho iya ixhomekeke ngakumbi kwiziseko zonxibelelwano ezithembekileyo nezisebenzayo ukuxhasa imisebenzi yazo.Ngokunyuka okuthe gqolo komthamo wedatha kunye nesidingo sokuqhagamshelwa kwesantya esiphezulu, kuye kwaba yimfuneko ukuba ube nokutshintsha kwenethiwekhi olomeleleyo onokuhlangabezana nezi mfuno.Apha kulapho i-LIMEE entsha yokusebenza okuphezulu kwe-Ethernet Layer3 100G Switch iza kudlala.
Olu tshintsho olucekethekileyo lweLayer3 ludibanisa inkqubela phambili yamva nje kwitekhnoloji yenethiwekhi ukubonelela amashishini ngokusebenza okungenakuthelekiswa nanto, ukulinganisa, kunye nokuthembeka.Eyenzelwe ukujongana nokunyuka kwedatha yedatha, lo tshintsho luqhayisa i-bandwidth ye-100G, evumela uxhulumaniso olungenamthungo kunye nokudluliselwa kwedatha kwinethiwekhi.
Enye yezinto ezibalaseleyo zolu tshintsho kukukwazi kwayo Amandla phezu kwe-Ethernet (PoE).Kuthetha ukuba ayikwazi ukuhambisa idatha kuphela kodwa inika amandla kwizixhobo ezixhunyiwe ezifana neefowuni ze-IP, iindawo zokungena ezingenazintambo, kunye neekhamera zokhuseleko, ukuphelisa isidingo semithombo yamandla eyongezelelweyo.Oku akwenziwa lula kuphela inkqubo yofakelo kodwa ikwabonelela ngokuguquguquka ekubekweni kwesixhobo, kuyenza ibe sisisombululo esifanelekileyo kumashishini abo bonke ubungakanani.
Ke ngoko, unikezelo lwamandla amabini luqinisekisa ukuba uthungelwano luhlala lusebenza kwaye lusebenza nakwimeko yokusilela kombane.Oku kungasebenzi kuphelisa naliphi na ixesha lokunciphisa elinokwenzeka, ukuqinisekisa imveliso engaphazamisekiyo kunye nokunciphisa ilahleko.Ngokukwazi ukuphatha i-traffic network enzima kunye namandla ezixhobo ezininzi, olu tshintsho lubonelela ngoxolo lwengqondo kumashishini axhomekeke kwisiseko sothungelwano esithembekileyo.
Ukongeza kwiimpawu zayo eziphambili, olu tshintsho lweLayer3 lukwabonelela ngojongano lolawulo olulungele umsebenzisi, luvumela abalawuli ukuba baqwalasele ngokulula kwaye babeke iliso kwinethiwekhi.Ngeempawu ezifana nenkxaso ye-VLAN, ukubeka phambili kwe-QoS, kunye neeprothokholi zokhuseleko eziphambili, amashishini anokwandisa ukusebenza kwenethiwekhi kunye nokuqinisekisa ukuthembeka kwedatha.
Nge-LIMEE entsha yokusebenza okuphezulu kwe-Ethernet Layer3 100G Tshintshela, amashishini anobungqina bexesha elizayo kwiziseko zabo zenethiwekhi kunye nokuqinisekisa uxhulumaniso oluphezulu, ukuhanjiswa kwamandla, kunye nokulawulwa kwenethiwekhi.Nokuba lishishini elikhulu, iziko lemfundo, okanye ishishini elincinci, olu tshintsho luzisa ukusebenza okugqwesileyo kunye nokuthembeka, oko kuyenza ibe yi-asethi exabisekileyo kule mihla yedijithali.Ngoko, kutheni ulinda?Phucula kwi-Ethernet Layer3 100G entsha yokusebenza okuphezulu kwaye ufumane amandla onxibelelwano olungenamthungo kunye nokusebenza kwenethiwekhi okuphuculweyo namhlanje!
IiNkcazo zeMveliso | |
Ukonga amandla | Ukukwazi ukulala komgca we-Ethernet eluhlaza |
Ukutshintsha kweMAC | Lungiselela ngokuzinzileyo idilesi ye-MAC Ukufunda idilesi ye-MAC ngokukhawuleza Qwalasela ixesha lokuguga ledilesi ye-MAC Nciphisa inani ledilesi ye-MAC efundiweyo Uhluzo lwedilesi ye-MAC IEEE 802.1AE Ulawulo loKhuseleko lweMacSec |
I-Multicast | IGMP v1/v2/v3 IGMP Snooping IGMP ikhefu ngokukhawuleza I-MVR, i-Multicast filter Iipolisi ezininzi kunye nemida yeenombolo ezininzi Ukusasazwa kwetrafikhi okuninzi kuzo zonke iiVLAN |
VLAN | 4K VLAN GVRP QinQ, QinQ ekhethiweyo I-VLAN yabucala |
Ukungafuneki kweNethiwekhi | VRRP Ukhuseleko lwekhonkco lwe-ethernet oluzenzekelayo lwe-ERPS MSTP I-FlexLink MonitorLink 802.1D(STP),802.1W(RSTP),802.1S(MSTP) Ukukhuselwa kwe-BPDU, ukukhuselwa kweengcambu, ukukhuselwa kwe-loop |
I-DHCP | Iseva ye-DHCP I-DHCP Relay DHCP Client I-DHCP Snooping |
ACL | Umaleko 2, uLeya 3, kunye noMaleko 4 ACLs IPv4, IPv6 ACL VLAN ACL |
Umzila | IPV4/IPV6 iprothokholi yemfumba emibini IPv6 ummelwane ukufunyanwa, Indlela MTU ukufunyanwa Indlela engatshintshiyo, RIP/RIPng OSFPv2/v3,PIM indlela eguquguqukayo BGP, BFD for OSPF MLD V1/V2, MLD snooping |
QoS | Ukuhlelwa kwetrafikhi okusekwe kwimihlaba ekwisihloko seprotocol ye-L2/L3/L4 Umlinganiselo wezithuthi zemoto Phawula i-802.1P/DSCP ephambili SP/WRR/SP+WRR ukucwangcisa umgca Iindlela zokuthintela ukuxinana komsila kunye ne-WRED Ukujongwa kwetrafikhi kunye nokubunjwa kwetrafikhi |
Uphawu loKhuseleko | Ukuqatshelwa kwe-ACL kunye nokucoca indlela yokukhusela esekelwe kwi-L2 / L3 / L4 Ikhusela ekuhlaselweni kwe-DDoS, ukuhlaselwa kwe-TCP SYN yeSikhukula, kunye nokuhlaselwa kwe-UDP yeSikhukula Cindezela usasazo oluninzi, usasazo, kunye neepakethi ezingaziwayo zeunicast Ukwahlulwa kwezibuko Ukhuseleko lwezibuko, IP+MAC+isibophelelo sezibuko I-DHCP sooping, iDHCP inketho82 IEEE 802.1x isatifikethi Tacacs +/Radius ungqinisiso olukude lomsebenzisi, ukuqinisekiswa komsebenzisi wasekhaya I-Ethernet OAM 802.3AG (CFM), 802.3AH (EFM) ubhaqo lwekhonkco elihlukeneyo le-Ethernet |
Ukuthembeka | Ikhonkco lokudibanisa kwimo ye-static / LACP Ubhaqo lwekhonkco lwendlela enye ye-UDLD I-ERPS I-LLDP Ethernet OAM 1+1 ugcino lwamandla |
OAM | Console, Telnet, SSH2.0 ULawulo lweWEBHU I-SNMP v1/v2/v3 |
Ujongano Lwenyama | |
Izibuko le-UNI | 24*10GE, SFP + |
NNI Port | 2 * 40/100GE, QSFP28 |
Izibuko loLawulo lwe-CLI | RS232, RJ45 |
Indawo yokusebenza | |
sebenzisa i-temp | -15℃55℃ |
Ubushushu bokugcina | -40℃70℃ |
Ubuntu bezizalwane | 10%~90%(Akukho ukuxinana) |
Ukutya umbane | |
Ukunikezwa Amandla | 1+1 unikezelo lwamandla amabini, AC/DC amandla okuzikhethela |
Ubonelelo lwaMandla oNgeniso | AC: 90~264V, 47~67Hz;DC: -36V~-72V |
Ukutya umbane | Umthwalo opheleleyo ≤ 125W, ungasebenzi ≤ 25W |
Ubungakanani besakhiwo | |
Iqokobhe letyala | Igobolondo lesinyithi, ukupholisa umoya kunye nokutshatyalaliswa kobushushu |
Case dimension | 19 intshi 1U, 440*320*44 (mm) |